Temperature range: -20 ° C ~ 60 ° C
Humidity range: 00%~100%RH
Control accuracy: 0.1 °C 0.1% RH
Detection probe: integrated sensor
Output type: relay output
Output capacity: up to 10A
Function:
Product features are two main types of classification: the functions of temperature and humidity.
The function of temperature are as follows:
1. The automatic identification of work mode:
The system automatically according to the start/stop temperature, identify work mode;
Start temperature > stop temperature, cooling mode'C'.
Start temperature < stop temperature, heating mode 'H'.
2. Cooling mode:
When the temperatureStart temperature, relay conduction, red led on, refrigeration equipment begin to work;
When the temperatureStop temperature, relay disconnect, red led off, refrigeration equipment stop to work;
3. Heating mode:
When the temperatureStart temperature, relay conduction, red led on, heating equipment begin to work;
When the temperatureStop temperature, relay disconnect, red led off, heating equipment stop to work;
4. Temperature correction function OFE (-10.0 ~ 10):
The system is working for a long time and may be biased, through this function correctly, the actual temperature = measuring temperature + calibration value;
How to set the start/stop temperature:
1. In the running interface, Long Press ' TM+ ' key more than 3 seconds, into the start temperature settings interface, can be modified by TM+ TM-key, to be modified, waiting for 6s automatic exit and save;